Forge-1

A bounded research prototype for examining how equipment availability, controller state, and timing interact inside aggregate critical-power systems.

Program
01 / Power
Status
Active research prototype
System class
Aggregate critical power
Validation
Not validated for facility deployment

Critical power can survive isolated faults and still fail in combination.

Conventional contingency checks often examine individual component loss. Forge-1 is being developed to explore sequences in which equipment availability, controller thresholds, qualification delays, and transfer logic interact over time.

A bounded model of the transfer path.

  1. Utility
  2. Source qualification
  3. ATS / Breaker
  4. Critical bus
  5. Critical load
Supporting branch
Generator
Merges into ATS / Breaker
Supporting branch
Battery
UPS
Merges into Critical bus

Model inputs and outputs.

Input parameters

  • Equipment ratings and availability
  • UPS and battery capacity
  • Generator start and qualification timing
  • ATS and breaker states
  • Voltage and frequency thresholds
  • Transfer and lockout delays
  • Injected equipment and controller events

Output record

  • Deterministic execution trace
  • Controller-state transitions
  • Transfer timing
  • Critical-load service state
  • PASS / FAIL outcome
  • Machine-level failure reason
  • Explicit assumptions and model boundary

From initial state to forensic trace.

  1. 01

    Define

    Describe aggregate equipment, controller thresholds and timing assumptions.

  2. 02

    Inject

    Apply one or more equipment, sensing or controller events.

  3. 03

    Execute

    Advance the deterministic state model through qualification and transfer logic.

  4. 04

    Trace

    Preserve the state transitions, timing and outcome for engineering review.

Research boundary

FORGE-1 IS A RESEARCH PROTOTYPE. IT IS NOT AN ELECTRICAL-DESIGN, COMMISSIONING, OPERATIONAL-CONTROL, OR SAFETY TOOL. IT DOES NOT REPRESENT A COMPLETE FACILITY ONE-LINE DIAGRAM, PROTECTION-COORDINATION STUDY, OR ELECTROMAGNETIC-TRANSIENT MODEL. ALL OUTPUTS REQUIRE INDEPENDENT ENGINEERING REVIEW.

The active work is validation.

The immediate objective is to demonstrate that a bounded model can reproduce a known interacting failure sequence from declared inputs without hardcoding the final outcome.

Examine the model boundary with us.

For technical collaboration, independent reproduction, critical-power expertise, or serious questions about the program.